TRANSFORMERS INDOORS TYPE
Select a model to visualize its characteristics
 
CURRENT TRANSFORMER UP TO 3.3 kV.
Guide of selection up to 3.3 kV.
 
The data briefed in the application guide, must be interpreted like general indicatives of the possibilities of each type of transformer.
 
For each case in individual, to consult with our department of Engineering to define the Model adapted to its necessities.
 

Current transformers Indoors Type up to 3,3kV.

Application Range(Amp)

Power until (V.A)

Class

Security factor limit

Model

Data
5-5000
Under order
MTE

5-10 á 400-800

15/30

0.5/5p

5/10

MT1S

500 - 4000

30

0.5

5

MP4 Normalized interior diameter.

MP4 Special interior diameter.

500 - 4000

30/30

0.5/10p

5/10

MP4-R

 
NOTE: This selection is valid also for secondary of measurement in Class 0,5s..
 
NOTE II: The transforming can offer with bases without projections also respecting the measures limited in the planes.
 
CURRENT TRANSFORMER UP TO 13.2 kV.
Guide of selection up to 13,2 kV.
 
The data briefed in the application guide, must be interpreted like general indicatives of the possibilities of each type of transformer.
 

For each case in individual, to consult with our department of Engineering to define the Model adapted to its necessities.

 

Current transformers Indoors Type up to 13,2kV.

Application Range(Amp)

Power until (V.A)

Class

Security factor limit

Model

Data

5-10 á 300-600

30

0.5

5

MJ7

5-10 á 300-600

30/30

0.5/10p

5/10

MJ8 Secondary double, primary lineal.

MJ8 Secondary double, primary rhombus.

5-10 á 400-800

30/60

0.5/10p

5/10

MJ14 Secondary triple, primary lineal.

MJ14 Secondary triple, primary rhombus.

5-10 á 400-800

30/30/60

0.5/10p/10p

5/10/10

MJ14 Secondary triple, one independent.

MJ14 Secondary double.
MJ14 Secondary double, primary in rhombus.

500 á 4000

15/30/30

0.5/10p10p

5/10/10

MJ17 Length 390 mm.

MJ17 Length 440 mm.

5-10 á 600-1200

15/30

0.5/10p

5/10

ABK-10

1500 á 3000

15/30

0.5/10p

5/10

ABK-10

5-10 á 600-1200

30/60

0.5/10p

5/10

ABK-20R

1500 á 3000

30/60

0.5/10p

5/10

ABK-20R

5-10 á 600-1200

30/30/30

0.5/10p/10p

5/10/10

ABK-20E

1500 á 3000

30/30/30

0.5/10p/10p

5/10/10

ABK-20E

 
 
NOTE: This selection is valid also for secondary of measurement in Class 0,5s..
 

NOTE II: The transforming can offer with bases without projections also respecting the measures limited in the planes.

 
CURRENT TRANSFORMER UP TO 33 kV.
Guide of selection up to 33 kV.
 
The data briefed in the application guide, must be interpreted like general indicatives of the possibilities of each type of transformer.
 
For each case in individual, to consult with our department of Engineering to define the Model adapted to its necessities.
 

Current transformers Indoors Type up to 33kV.

Application Range(Amp)

Power until (V.A)

Class

Security factor limit

Model

Data
5-10 á 300-600 30/30 0.5/10p 5/10 MJ35 Primary in Rhombus. View Details

5-10 á 400-800

30/60

0.5/10p

5/10

MJ35 Primary Lineal.

MJ35 Primary in Rhombus.

5-10 á 400-800

30/30/60

0.5/10p/10p

5/10/10

MJ35 Primary Lineal.

MJ35 Primary in Rhombus.

5-10 á 600-1200

30/30/30

0.5/10p/10p

5/10/10

ABK35

1500 á 3000

30/30/30

0.5/10p/10P

5/10/10

ABK35

 
NOTE: This selection is valid also for secondary of measurement in Class 0,5s..
 
VOLTAGE TRANSFORMER UP TO 13.2 kV.
Guide of selection up to13,2 kV.
 
The data briefed in the application guide, must be interpreted like general indicatives of the possibilities of each type of transformer.
 

For each case in individual, to consult with our department of Engineering to define the Model adapted to its necessities.

 

Voltage transformers Indoors Type up 13.2kV.

Rango de
aplic.
(kV)

Power until (VA)

Class

Voltage factor

Fuse

Model

Data
2.3/0.11 á 6.6/0.11
60
0.5
1,2xUn
No
MV6-U View Details

2.3/0.11 á 13.2/0.11

100

0.5

1,2xUn

Yes

MV3-BF

2.3/0.11 á 13.2/0.11

100

0.5

1,2xUn

No

MV3

2.3/0.11 á 13.2/0.11
V3   V3       V3   V3

60

0.5

1,2xUn

Yes

MV3-UF

2.3/0.11 á 13.2/0.11
V3   V3      V3   V3

60

0.5

1,2xUn

No

MV6-U

2.3/0.11 á 13.2/0.11
V3   V3       V3   V3

100

0.5

1,2xUn

Yes

MV3

2.3/0.11 á 13.2/0.11
V3    V3      V3  V3

100

0.5

1,2xUn

No

MV3

 
NOTE: The transforming can offer with bases without projections also respecting the measures limited in the planes.
 
VOLTAGE TRANSFORMER UP TO 33 kV.
Guide of selection up to 33 kV.
 
The data briefed in the application guide, must be interpreted like general indicatives of the possibilities of each type of transformer.
 

For each case in individual, to consult with our department of Engineering to define the Model adapted to its necessities.

 

Voltage transformers Indoors Type up 33kV.

Rango de
aplic.
(kV)

Power until (VA)

Class

Voltage factor

Fuse

Model

Data

33/0.11

100

0.5

1,2xUn

No

MV35

33/0.11
V3 . V3

100

0.5

1,2xUn

Yes

MV35

33/0.11
V3 . V3

100

0.5

1,2xUn

No

MV35

33 / 0.11 0.11
V3 . V3 - V3
30/60
0,2/3P - 0,5/3P
1,2xUn
No
MV35 View Details
 
NOTE: The transforming can offer with bases without projections also respecting the measures limited in the planes.
 